QUICKTRONIC
®
Intelligent DALI DIM | Introduction
4
1.1 Dimmable lighting installations
Dimmable electronic control gears (DIM ECGs) are playing
an increasingly important role in all modern lighting tech-
nology applications. Dimmable ECGs from OSRAM inte-
grated into the building management are at the heart of an
intelligent lighting system that creates up to 80% energy
savings compared to solutions with conventional control
gears. The reason for this is that many requirements for
lighting installations can be easily and elegantly realized
with a light management system. Economy, light comfort,
reliability and safety are the driving forces behind it.
1.1.1 Economy
Intelligent, energy-saving concepts in building manage-
ment considerably reduce lighting costs:
Up to 50 % lower power consumption than when
operated with magnetic, conventional control gears
(CCG operation)
More than 50 % longer lifetime than conventional
control gears (CCGs) and low-loss conventional
control gears (LLCG) as a result of gentle operation
Low maintenance costs
Reduction of energy costs for air-conditioning units
by reducing the cooling load
Intelligent components:
Extremely low standby energy demand (< 0.2 W)
SMART GRID
POWER2LAMP
Emergency lighting (EL)
Corridor function
Touch DIM function
1.1.2 Lighting comfort
Lighting situations at the touch of a button (lighting
scenes), including integrated motion detection and day-
light/time-dependent control increase lighting comfort.
The properties of a high-quality dimmable ECG include:
Flicker-free start
Pleasant, continuously dimmable (1(3)100 %)
and fl icker-free light without stroboscopic effects
Practically free of noise, no annoying humming from
choke in CCG/LLCG
No fl ashing of faulty lamps
Automatic restart after lamp replacement
Easy of use, feedback to the control unit and settings
for personal lighting values create individuality
1 Introduction
ECG DIM ECG DIM ECG and
sensor
CCG
Worldwide energy savings potential with
dimmable control gears
Changing from CCG (T8) > ECG (T8) >
DIM ECG (T5) > DIM ECG with sensor (T5)
0
50
100
200
150
300
350
400
250
100 %
75 %
50 %
20 %
200 million tons CO
2
80 % energy savings =
80 % CO
2
reduction
40 million tons CO
2
Worldwide energy savings potential with dimmable
control gears
0
100
Power consumption
Energy savings of up to 80 % with daylight and motion detection light
management system
Power consumption
Presence
8:00
Time
12:00 20:00
Daylight
intensity
* With daylight and motion detection light management system
Energy
consumption*